Showing posts with label PreVent. Show all posts
Showing posts with label PreVent. Show all posts

Saturday, 30 May 2015

Where can I use a RABΞScreen BHA or BHC air intake filter screen?

RABΞScreens


RABΞScreen Protection stops debris before it costs you time, energy & money



Where can I use a RABΞScreen BHA or BHC air intake filter screen?

Anywhere that you have air movement. It does not matter what shape or size of opening we can design an air intake screen to suit every application. Dry air coolers, chillers, air handling units, condensers, cooling towers, intake louvres and air intakes of any design.
BHA – single layer of black, high abrasion polymer coated, polyester mesh. Black Pvc Coated High Abrasion Media is a 9x9 1000 Denier Multi Polymer Coated Polyester Mesh. The air flow resistance of a clean BHA air intake screen single layer is as follows:
0.50m/s               1.25pa
2.03m/s               8.75pa
3.05m/s               17.00pa

BHC – single layer black huckaback woven polypropylene. Black Polypropylene HoneyComb Weave is  a three Dimensional Polypropylene Honey Comb Weave which has a low air flow resistance whilst the electrostatic charge attracts  airborne debris. 
It can also be supplied in multiple layers of media to improve particle capture of 3 micron particles to 93%.  The air flow resistance of a clean BHC air intake screen single layer is as follows:

0.50m/s             1.25pa
2.03m/s             12.45pa
3.05m/s             22.42pa

Where would you use BHA or BHC?

The BHA air intake filters can only be used in a single layer  but it is a high abrasion filter and is perfect for the majority of applications where seed, pollen, leaves and insects are an issue. 

The BHC air intake screen is for use where fine particulate is a problem and a multiple layer filtration solution is required.  Ideal for fine cement, flour,  copier ink and other extra fine particulate.




Tuesday, 31 March 2015

Air Intake Filter Screens Prevent® and solve air intake problems


Permatron manufactures some of the world's leading air filters which are used to protect expensive HVAC equipment by stopping debris at air intakes - before it has a chance to enter the system.

Today more than ever before, mechanical, maintenance and process engineers are being challenged to provide effective solutions that help to optimise environmental air quality and process cooling efficiency, while reducing downtime and maintenance cost.

Regardless of the technology used to process incoming fresh air, the challenge has always been keeping cooling towers and other HVAC systems clean. When fresh air is drawn from the outside into HVAC systems, it brings along with it a wide range of airborne debris that can impact air quality and quickly clog the system. A clogged HVAC system ultimately leads to downtime for cleaning and maintenance.

In facilities that rely upon process cooling for robotic assembly, injection moulding or other production applications, downtime due to HVAC system fouling is particularly costly because of lost productivity.

Air intake problems are usually seasonal in nature. The times of year that represent the greatest maintenance challenge are spring, summer and autumn. Depending upon the season and region of the country, different environmental factors come into play.

In the spring, nesting birds are frequently problematic (especially in cooling towers). In areas where spruce trees exist, you can count on seed being a problem during the summer.



In wetland regions, insects are frequently problematic during spring and summer and in rural farming areas, leaves, pollen and crop harvest debris can be problematic during the summer and autumn.



Maintaining good air and water ecology are important elements in managing healthy and efficient HVAC systems. However, until recently, most businesses and institutions could do little to improve the quality of the air before it entered their systems. Hence entry of airborne debris places greater demand on the HVAC maintenance process.

Unlike traditional internal filter banks used in air handling units, air intake filters are installed on HVAC systems at the point where fresh air enters into the system thus filtering out debris before it can become a problem.




Air intake filters can also be installed on cooling towers, air-cooled chillers and condenser units or any fresh air intake opening. Air intake filtration is specifically designed to stop spruce seed, pollen, leaves, insects, birds, paper, construction debris and other airborne matter from being drawn into air intake openings.

Originally published by Permatron Chicago - Filtration Solutions since 1957

Friday, 6 March 2015

Small investments, huge savings



The Health Estate Journal recently ran an article under the heading "Small investments, huge savings". 

It states that one of the key conclusions from the IHEEM Healthcare Estates 2014 conference was that basic energy efficiency measures could "shave millions of pounds from NHS estates' running costs", and that hospitals and other healthcare buildings face both "an air conditioning legal crisis", and a growing threat from outdoor air pollution.   

The whole article is very much worth a read, but one of the key statements is that there is plenty of "low hanging fruit" that any hospital can use to quickly, and cheaply improve energy efficiency. 

This last statement is so very true. 

Hospitals are a 24/7 operation and have a significant need for cooling which can be found at the heart of most HVAC systems.  

In a recent example we surveyed two separate cooling systems at the same facility comprising 1 x Alfa Laval Fin coil unit SCAG-8-5 and 4 x Carrier 09GHCA-178. 
 
The annual energy consumption for these cooling systems totalled 1,618,000 kWh which costs the trust just over £194K per annum to run. 

As you can see from the images below the horizontal coil faces were dirty with compacted dust, seed, pollen and other debris drawn into the fins. 



In a USA study by Pacific Gas and Electric they identified that 1mm of debris on a coil fin would cause a 21% drop in efficiency and increase energy consumption by as much as 30%.    

“When a condenser is dirty or unable to reject heat or energy, heat increases both the temperature and pressure of the refrigerant liquid line. The higher total energy, increases the flash gas that decreases system efficiency and capacity” http://www.refrigtech.com/Knowledge_Center/Knowledge_Characteristics_Evaporators.pdf  

That is why this forward thinking trust contacted RABSE distributor Advantiv to solve the problem of coil clogging and reduce the cost of running their plant. 

By installing an air intake filter screen to protect the coil faces, contamination will be significantly reduced as the cooling season progresses. 

The air intake screen is manufactured using a polyester core and polypropylene overlay which, during air movement, creates a static charge. This electrostatic charge easily captures the airborne particulate to PreVent® it getting through to the fins. 

No airflow, no electrostatic charge and this enables maintenance personnel to easily clean the air intake screens using a vacuum cleaner, hose or brush.  

By comparing with similar sites we would expect to see a minimum 10% reduction in running cost as the condenser is kept clean and efficiently rejects heat. 

The air intake filter screens were secured to the coil support steelwork using marine grade, nylon drop tab fastenings. In the event that access to the fins is required the screens can be easily removed and replaced.

With an air resistance of only 17 pascals at 3.05m3/s this highly effective external filter will continue to protect the coils for at least 10 years and produce an ROI of less than 12 months. 

That leaves the trust with savings of at least £175K over the next 9 years and why we are proud to be saving money for the NHS.

Richard Betts
Managing Director – RAB Specialist Engineers Limited
01635 248633

Monday, 16 February 2015

Experts. Are we just experienced or are we experts?


Experts. Are we just experienced or are we experts?


I saw this recent comment from a multi-trade specialist who are able to offer a range of services to the building services market.

Their comment says

"Contact our team of experts today and book your free"..............

I am always concerned when someone offers a free anything because invariably this WILL end up costing money because someone always ends up paying for it. 

If you are offering to survey a project that requires the installation of anything to anything then how can you realistically cost the job without seeing it? 
Unless of course you are working to detailed drawings. 

One of my ex-employees (Technical Director) once saw two water tanks. Unfortunately he only charged the customer for one, so even that doesn't always work.  

Anyway let's get back to experts. 



The word “expert” is formed from the conjunction of two roots which, phonetically, can be represented as “x” and “spurt”. Everyone knows that “X” is an unknown quantity, and that a “spurt” is what one gets from squeezing a drop of water. Therefore, an expert is an unknown drip under pressure.  

Definition: Expert from an article by Jerry Cates , first published on 24 August 2011

As Jerry says the above definition although amusing is not entirely correct.

Another definition from Brainy Quote suggests

Taught by use, practice, or experience, experienced; having facility of operation or performance from practice; knowing and ready from much practice; clever; skilful; as, an expert surgeon; expert in chess or archery.

However if you look at Wikipedia then:
"In line with the socially constructed view of expertise, expertise can also be understood as a form of power; that is, experts have the ability to influence others as a result of their defined social status. By a similar token, a fear of experts can arise from fear of an intellectual elite's power". 


We all seek advice all of the time because let’s face it that is the only way to learn.

If you are selling a safety product then it is easy to influence others based upon your level of experience. 

By carefully wording the proposal you can generate a fear factor.

Is that being an expert or commercial bullying?



At RAB we offer advice based upon our own experience and have even stated:

 "
Technical expertise - the best people for the best service and the best finish"

But, are we truly experts or just very experienced at what we do?


That choice is one that we have to leave to our clients. 

Take a look at  www.rabse.com and www.airintakescreen.co.uk and make your own decision once you have spoken to one of our very experienced people.

And finally "An expert is a man who has made all the mistakes which can be made, in a narrow field". 


Monday, 15 December 2014

It's a rat trap

There are not too many contracts where you have to consider rats as a potential hazard.

In this particular barn the water pipe feeding the cows and pigs ran through galvanised steel caps fitted tightly to the pen walls. When I say tightly, that was the assumption which was so badly wrong.

The water pipe was 25mm Blue MDPE which was layered with frost protection trace heating cable and mineral fibre insulation sections. Regrettably the sealed metallic capping had been modified to allow cables and outlets to be fitted and this allowed the rats to enter this dark and warm place next to a ready supply of food and water.



This capping ran in multiple lines over an 80m length and the Barn Town Rats thrived in the Rat Run.


These rodents need plenty of water and must also keep gnawing to wear down their teeth. What better place than a dark duct with mineral fibre for nesting, trace heating cable at low amps for chewing and of course water pipe for gnawing. And if it gets too wet, then move further up the duct and chew, gnaw, nest some more. 



So back to the job.

Repair / replace missing insulation from exposed pipework, disconnect redundant pipes where dead legs were in place and carry out minor repairs to trace heating cable. The exposed areas were simple enough and there was only minor damage to the cabling. There was some evidence of long deserted nests and so we were armed with the appropriate PPE - coveralls, splash goggles and chemically resistant gloves – which, with a fetching pair of white wellingtons, made a significant fashion statement.

However, to remove the dead legs we needed to also remove the steel caps. That is when we disturbed the rats and found that the visible nests were just the tip of the iceberg.  

The morning after the steam cleaning machine had broken as the rats had made a new nest and gnawed the power cable. This was not a job for RAB and so a local contractor called Extreme Environmental were called in to assist. They stripped off the metalwork, cleared out the nests and cleaned the pipework and walls with a disinfectant and biocide.



They looked like people from an Ebola outbreak station with their facemasks, full body coveralls, boots, safety goggles and gloves but, as rat mess contains particularly harmful diseases, it was the only way to tackle the problem.  Whilst they were cleaning and making safe they also discovered further damage to the electrical cabling, trace heating cable and junction boxes. More leaks appeared as we stripped the steel ducting away from the walls and the job started to grow substantially.

No longer was it a minor repair as we needed to make safe the cabling, remove rat damaged and wet insulation and repair a lot of pipework leaks.  And, as any pipefitter will tell you, as you repair one weak point and refill the system the next weak point fails leading to more repairs. 



Oh yes and what of Big Bertha. She was the only rat who did not run away when we disturbed her nesting point. Instead, she just stared straight at me and did not move a muscle. And yes she was alive and no I was not braver than she was. 



That is why the farmer was called to do what farmers do best and us lightweight engineering types did a swift exit from the building. 

Monday, 24 November 2014

Fan Shroud Air Intake Filter Screen Stops Dust Blowing



Fan Shroud Air Filter Stops Dust Blowing


The Challenge - Recirculating Dust with Cooling Fan


Processing plant items manufactured with heat require high velocity air cooling from recirculating fans blowing directly onto the product before it can be packaged.  

Unfortunately the mobile and pedestal style air circulator fan components become covered in airborne debris as the equipment draws in the local air, picking up the particles which are then spread throughout the motor, blades and fan guards. 

These contaminants can, potentially, be blown back into the cooling area and onto the finished product.


Air intake screen fan shroud

 

The Solution - Fan Shroud Air Filter



Custom sized to fit securely on the backside of a fan guard, the filter wraps around the motor encasement and is held securely in place with an elastic edge and hook/loop attachment.  

Available in a washable woven electrostatic polypropylene media or disposable nonwoven polyester, the fan shroud attracts and holds the particles before they can enter the equipment. 

Easily removed, the washable filters can be changed out with a second set of filters as needed, rinsed and reused.  

The disposable polyester fan shrouds can be removed and disposed of depending on which model best meets the factory needs.  

Both the equipment and the product stay clean.

Inspection guidelines will include that Dust Collection & Filtering Devices be put in place to prevent possible contamination to food products from threads, lint and fibres.  

In GENERAL RULES FOR ALL FOOD PREMISES & FOODSTUFFS - the layout, design, construction, siting and size of food premises are to:


  1. Permit adequate maintenance, cleaning and/or disinfection, avoid or minimise air borne contamination, and provide adequate working space to allow for the hygienic performance of all operations.
  2. Be such as to protect against the accumulation of dirt, contact with toxic materials, the shedding of particles into food and the formation of condensation or undesirable mould on surfaces.

PreVent® Equipment Protection bonnet filters are one positive solution to this problem. For details please see Bonnet Filters