Tuesday, 16 December 2014
Air Intake Screens: Sampling the benefit
Air Intake Screens: Sampling the benefit: The problem with a relatively new product, even one that has been in the market for more than two years, is that most people do not tr...
Monday, 15 December 2014
It's a rat trap
There are not too many contracts where you have to consider
rats as a potential hazard.
In this particular barn the water pipe feeding the cows and
pigs ran through galvanised steel caps fitted tightly to the pen walls. When I
say tightly, that was the assumption which was so badly wrong.
The water pipe was 25mm Blue MDPE which was layered with
frost protection trace heating cable and mineral fibre insulation sections.
Regrettably the sealed metallic capping had been modified to allow cables and
outlets to be fitted and this allowed the rats to enter this dark and warm
place next to a ready supply of food and water.
This capping ran in multiple lines over an 80m length and
the Barn Town Rats thrived in the Rat Run.
These rodents need plenty of water and must also keep
gnawing to wear down their teeth. What better place than a dark duct with
mineral fibre for nesting, trace heating cable at low amps for chewing and of
course water pipe for gnawing. And if it gets too wet, then move further up the
duct and chew, gnaw, nest some more.
So back to the job.
Repair / replace missing insulation from exposed pipework,
disconnect redundant pipes where dead legs were in place and carry out minor
repairs to trace heating cable. The exposed areas were simple enough and there
was only minor damage to the cabling. There was some evidence of long deserted
nests and so we were armed with the appropriate PPE - coveralls, splash goggles
and chemically resistant gloves – which, with a fetching pair of white
wellingtons, made a significant fashion statement.
However, to remove the dead legs we needed to also remove
the steel caps. That is when we disturbed the rats and found that the visible nests
were just the tip of the iceberg.
The morning after the steam cleaning machine had broken as
the rats had made a new nest and gnawed the power cable. This was not a job for
RAB and so a local contractor called Extreme Environmental were called in to
assist. They stripped off the metalwork, cleared out the nests and cleaned the
pipework and walls with a disinfectant and biocide.
They looked like people from an Ebola outbreak station with
their facemasks, full body coveralls, boots, safety goggles and gloves but, as
rat mess contains particularly harmful diseases, it was the only way to tackle
the problem. Whilst they were cleaning
and making safe they also discovered further damage to the electrical cabling,
trace heating cable and junction boxes. More leaks appeared as we stripped the
steel ducting away from the walls and the job started to grow substantially.
No longer was it a minor repair as we needed to make safe
the cabling, remove rat damaged and wet insulation and repair a lot of pipework
leaks. And, as any pipefitter will tell
you, as you repair one weak point and refill the system the next weak point
fails leading to more repairs.
Oh yes and what of Big Bertha. She was the only rat who did
not run away when we disturbed her nesting point. Instead, she just stared
straight at me and did not move a muscle. And yes she was alive and no I was
not braver than she was.
That is why the farmer was called to do what farmers do best
and us lightweight engineering types did a swift exit from the building.
Tuesday, 25 November 2014
RAB Specialist Engineers: Fan Shroud Air Intake Filter Screen Stops Dust Blo...
RAB Specialist Engineers: Fan Shroud Air Intake Filter Screen Stops Dust Blo...: Fan Shroud Air Filter Stops Dust Blowing The Challenge - Recirculating Dust with Cooling Fan Processing plant items manu...
Monday, 24 November 2014
Fan Shroud Air Intake Filter Screen Stops Dust Blowing
Fan Shroud Air Filter Stops Dust Blowing
The Challenge - Recirculating Dust with Cooling Fan
Processing
plant items manufactured with heat require high velocity air cooling from
recirculating fans blowing directly onto the product before it can be
packaged.
Unfortunately the mobile and pedestal style air circulator fan
components become covered in airborne debris as the equipment draws in the local air, picking up the particles which are then spread throughout the
motor, blades and fan guards.
These contaminants can, potentially, be blown back into the
cooling area and onto the finished product.
The Solution - Fan Shroud Air Filter
Custom
sized to fit securely on the backside of a fan guard, the filter wraps around
the motor encasement and is held securely in place with an elastic edge and
hook/loop attachment.
Available in a washable woven electrostatic
polypropylene media or disposable nonwoven polyester, the fan shroud attracts
and holds the particles before they can enter the equipment.
Easily removed, the washable filters can
be changed out with a second set of filters as needed, rinsed and reused.
The disposable polyester
fan shrouds can be removed and disposed of depending on which model best
meets the factory needs.
Both the equipment and the product stay clean.
In GENERAL RULES FOR ALL FOOD PREMISES & FOODSTUFFS - the
layout, design, construction, siting and size of food premises are to:
- Permit adequate maintenance, cleaning and/or disinfection, avoid or minimise air borne contamination, and provide adequate working space to allow for the hygienic performance of all operations.
- Be such as to protect against the accumulation of dirt, contact with toxic materials, the shedding of particles into food and the formation of condensation or undesirable mould on surfaces.
PreVent® Equipment Protection bonnet
filters are one positive solution to this problem. For details please see Bonnet Filters