Tuesday, 16 December 2014

Air Intake Screens: Sampling the benefit

Air Intake Screens: Sampling the benefit: The problem with a relatively new product, even one that has been in the market for more than two years, is that most people do not tr...

Monday, 15 December 2014

It's a rat trap

There are not too many contracts where you have to consider rats as a potential hazard.

In this particular barn the water pipe feeding the cows and pigs ran through galvanised steel caps fitted tightly to the pen walls. When I say tightly, that was the assumption which was so badly wrong.

The water pipe was 25mm Blue MDPE which was layered with frost protection trace heating cable and mineral fibre insulation sections. Regrettably the sealed metallic capping had been modified to allow cables and outlets to be fitted and this allowed the rats to enter this dark and warm place next to a ready supply of food and water.



This capping ran in multiple lines over an 80m length and the Barn Town Rats thrived in the Rat Run.


These rodents need plenty of water and must also keep gnawing to wear down their teeth. What better place than a dark duct with mineral fibre for nesting, trace heating cable at low amps for chewing and of course water pipe for gnawing. And if it gets too wet, then move further up the duct and chew, gnaw, nest some more. 



So back to the job.

Repair / replace missing insulation from exposed pipework, disconnect redundant pipes where dead legs were in place and carry out minor repairs to trace heating cable. The exposed areas were simple enough and there was only minor damage to the cabling. There was some evidence of long deserted nests and so we were armed with the appropriate PPE - coveralls, splash goggles and chemically resistant gloves – which, with a fetching pair of white wellingtons, made a significant fashion statement.

However, to remove the dead legs we needed to also remove the steel caps. That is when we disturbed the rats and found that the visible nests were just the tip of the iceberg.  

The morning after the steam cleaning machine had broken as the rats had made a new nest and gnawed the power cable. This was not a job for RAB and so a local contractor called Extreme Environmental were called in to assist. They stripped off the metalwork, cleared out the nests and cleaned the pipework and walls with a disinfectant and biocide.



They looked like people from an Ebola outbreak station with their facemasks, full body coveralls, boots, safety goggles and gloves but, as rat mess contains particularly harmful diseases, it was the only way to tackle the problem.  Whilst they were cleaning and making safe they also discovered further damage to the electrical cabling, trace heating cable and junction boxes. More leaks appeared as we stripped the steel ducting away from the walls and the job started to grow substantially.

No longer was it a minor repair as we needed to make safe the cabling, remove rat damaged and wet insulation and repair a lot of pipework leaks.  And, as any pipefitter will tell you, as you repair one weak point and refill the system the next weak point fails leading to more repairs. 



Oh yes and what of Big Bertha. She was the only rat who did not run away when we disturbed her nesting point. Instead, she just stared straight at me and did not move a muscle. And yes she was alive and no I was not braver than she was. 



That is why the farmer was called to do what farmers do best and us lightweight engineering types did a swift exit from the building. 

Monday, 24 November 2014

Fan Shroud Air Intake Filter Screen Stops Dust Blowing



Fan Shroud Air Filter Stops Dust Blowing


The Challenge - Recirculating Dust with Cooling Fan


Processing plant items manufactured with heat require high velocity air cooling from recirculating fans blowing directly onto the product before it can be packaged.  

Unfortunately the mobile and pedestal style air circulator fan components become covered in airborne debris as the equipment draws in the local air, picking up the particles which are then spread throughout the motor, blades and fan guards. 

These contaminants can, potentially, be blown back into the cooling area and onto the finished product.


Air intake screen fan shroud

 

The Solution - Fan Shroud Air Filter



Custom sized to fit securely on the backside of a fan guard, the filter wraps around the motor encasement and is held securely in place with an elastic edge and hook/loop attachment.  

Available in a washable woven electrostatic polypropylene media or disposable nonwoven polyester, the fan shroud attracts and holds the particles before they can enter the equipment. 

Easily removed, the washable filters can be changed out with a second set of filters as needed, rinsed and reused.  

The disposable polyester fan shrouds can be removed and disposed of depending on which model best meets the factory needs.  

Both the equipment and the product stay clean.

Inspection guidelines will include that Dust Collection & Filtering Devices be put in place to prevent possible contamination to food products from threads, lint and fibres.  

In GENERAL RULES FOR ALL FOOD PREMISES & FOODSTUFFS - the layout, design, construction, siting and size of food premises are to:


  1. Permit adequate maintenance, cleaning and/or disinfection, avoid or minimise air borne contamination, and provide adequate working space to allow for the hygienic performance of all operations.
  2. Be such as to protect against the accumulation of dirt, contact with toxic materials, the shedding of particles into food and the formation of condensation or undesirable mould on surfaces.

PreVent® Equipment Protection bonnet filters are one positive solution to this problem. For details please see Bonnet Filters